Grease Trap Due
Restaurant grease trap sizing calculator
Use this restaurant grease trap sizing calculator to estimate indoor hydromechanical flow ratings in gallons per minute (GPM) and grease retention pounds under PDI-G101, or switch to the Uniform Plumbing Code (UPC) gravity method to size outdoor underground interceptors from connected Drainage Fixture Units (DFUs) and peak hourly meal volume. Tap a one-click preset for a coffee bar, fast-casual burger line, or full-service scullery to compare real fixture math immediately.
Sizing Method & Fixture Inputs
Zero login requiredFormula notice: PDI-G101 divides working sink volume (L × W × D × bowls ÷ 231 × fill) by drain minutes; UPC Table 1014.3.6 maps connected DFUs to gravity vault gallons. Your local plumbing official or pretreatment engineer approves final equipment sizing.
PDI-G101 Hydromechanical Rating
100 GPM / 200 lb PDI Hydromechanical Unit
Calculated at 86.5 GPM (75% sink fill, 1-min drain). Verify whether your local wastewater authority permits indoor hydromechanical units or requires an outdoor gravity tank.
- Calculated Peak Flow
- 86.5 GPM
- Sink 78.5 GPM + 8 extra
- Min Grease Retention (2× GPM)
- 200 lbs
- Standard 100 GPM HGI
- UPC Table 1014.3.6 Vault
- 1,000 gal
- Based on 28 connected DFUs
- Peak-Meal Vault Cross-Check
- 500 gal
- 85 peak-hr meals
Pre-fill this unit into your one-page pumping log
Carry "Fast Casual Main Kitchen" (140 gal) straight into a printable binder PDF plus 30, 7, and 1-day pump-out email reminders.
Annual emails the worksheet and sends reminders 30, 7, and 1 days before the date you enter.
Free .ICS requires no email or card. Paid plans email a printable FOG pumping log PDF within 5 minutes + 30/7/1-day email reminders with no hidden overage fees.
Sizing determines both upfront equipment space and ongoing service logistics. Once a trap or exterior vault is installed, a permitted liquid-waste hauler services the tank and leaves a grease trap manifest, while your manager tracks the tank gallon figure and next due date inside a binder. Published hauler visit prices read 2026-11-13 were about $150 to $500 in El Paso, $200 to $500 in Boise, and $225 to $450 in Fairhope—private vendor visit ranges, never a municipal sizing rule.
This calculator is an independent planning aid, not a stamped engineering submittal or municipal permit check. Local sewer districts and building departments always hold final authority over approved interceptor models and capacities.
Build my pre-filled pumping log PDF
PDI-G101 vs. Uniform Plumbing Code (UPC) Sizing Formula Reference
Plumbing engineers and municipal wastewater reviewers choose between two sizing methods depending on whether a kitchen qualifies for an indoor hydromechanical unit or requires an outdoor underground gravity tank.
| Parameter | PDI-G101 Hydromechanical (HGI) | UPC Chapter 10 Gravity (GGI) |
|---|---|---|
| Core Formula | GPM = (L × W × D × Bowls ÷ 231) × 0.75 ÷ Drain Min | UPC Table 1014.3.6 Connected DFUs → Vault Gallons |
| Grease Retention Rule | Minimum pounds of grease = 2 × GPM (e.g., 35 GPM = 70 lb) | Liquid retention volume from 500 gal up to 3,000+ gal |
| Typical Equipment Location | Indoors under 3-compartment sink or recessed in kitchen floor | Outdoors underground beneath parking lot, alley, or loading zone |
| Best-Fit Establishments | Coffee bars, bakeries, sandwich counters, low-grease prep lines | Full-service dining, fryers, woks, charbroilers, high-temp dishmachines |
| UPC DFU Step Benchmarks | Up to 100 GPM rated flow (200 lb grease capacity ceiling) | 1–8 DFU: 500 gal · 9–21 DFU: 750 gal · 22–35 DFU: 1,000 gal · 36–90 DFU: 1,250 gal · 91–172 DFU: 1,500 gal |
Run the companion kitchen compliance calculators
All calculators hub →25% FOG + Sludge
25 Percent FOG Rule Tracker
Measure floating grease cap plus bottom solids against total liquid depth, view a live tank cross-section gauge, and project the calendar date your trap hits 25%.
Open Combined FOG % + Due Date →
Annual Budget
Commercial Grease Trap Pumping Cost Estimator
Model per-visit and yearly hauler spend across indoor hydromechanical traps (20-100 lb) and outdoor gravity vaults (500-2,000+ gal) with regional and surcharge factors.
Open Visit Range + Annual Budget →
Keep with the receipt
25 percent FOG rule tracker
Check floating grease cap plus settled solids against total tank depth and project your 25% threshold date.
Keep with the receipt
commercial grease trap pumping cost
Estimate per-visit and yearly pumping spend for the indoor lb or outdoor gallon size you just calculated.
Keep with the receipt
all grease trap calculators
Switch between sizing, 25% FOG depth tracking, and annual hauler budget planning on one hub.
Keep with the receipt
grease trap cleaning
Permitted hauler questions, published company visit ranges, and how the one-page binder log works.
Keep with the receipt
grease trap manifest
Keep signed hauler tickets indexed next to your trap gallon rating and binder filing location.
Keep with the receipt
grease interceptor pumping log
Outdoor underground vault log template for 500 to 3,000+ gallon gravity interceptors.
How the PDI-G101 sink compartment formula calculates GPM and pounds
For small indoor hydromechanical grease interceptors (HGIs) installed beneath a three-compartment pot sink or recessed into a prep-room floor, plumbing reviewers commonly apply the Plumbing and Drainage Institute PDI-G101 volumetric steps. First, multiply compartment length by width by water depth in inches, then multiply by the number of compartments to obtain total fixture volume in cubic inches.
Second, divide total cubic inches by 231—the exact number of cubic inches in one US liquid gallon—to find rim-full gallon capacity. Third, multiply by 0.75 to account for the standard 75 percent working displacement fill factor when dishes and pots sit in the wash, rinse, and sanitize bowls (or select 100 percent when a strict local reviewer checks rim-full flood discharge).
Fourth, divide effective gallons by the allowed drainage period—either a 1-minute fast commercial pull or a 2-minute standard drain cycle—and add any continuous GPM discharge from connected pre-rinse sprayers or dishmachines where allowed by code. Finally, round up to the next standard PDI flow rating (4, 7, 10, 15, 20, 25, 35, 50, 75, or 100 GPM) and multiply GPM by 2 to determine minimum required grease retention in pounds.
Why a 1-minute versus 2-minute drain period doubles your trap rating
One dropdown accounts for the single biggest surprise during restaurant plan review: drainage time. Consider a standard three-compartment commercial sink measuring 24 by 24 by 14 inches per bowl. Three bowls hold 24,192 cubic inches, or 104.7 rim-full gallons, which equals 78.5 working gallons at 75 percent fill.
Under a 2-minute drainage allowance, 78.5 gallons requires 39.3 GPM—stepping up to a 50 GPM / 100-pound indoor hydromechanical unit. Under a strict 1-minute drainage code with an 8 GPM pre-rinse line running simultaneously, peak flow reaches 86.5 GPM, requiring a 100 GPM / 200-pound unit or triggering a mandatory step-up to an outdoor gravity grease interceptor. Checking which drain period your building department enforces prevents buying an under-rated cabinet trap before rough-in inspection.
When Uniform Plumbing Code DFU tables require an outdoor gravity tank
Full-service kitchens running high-temperature rack dishmachines, tilt braising pans, wok ranges, rotisseries, and banks of deep fryers discharge hot emulsified fats and heavy food solids that overwhelm compact indoor baffles. Jurisdictions adopting Uniform Plumbing Code Chapter 10 (Table 1014.3.6) size outdoor Gravity Grease Interceptors (GGIs) by summing the Drainage Fixture Units (DFUs) of every grease-bearing fixture tied to the kitchen grease waste line.
In UPC Table 1014.3.6, 1 to 8 DFUs map to a 500-gallon tank, 9 to 21 DFUs map to 750 gallons, 22 to 35 DFUs map to 1,000 gallons, 36 to 90 DFUs map to 1,250 gallons, and 91 to 172 DFUs map to 1,500 gallons, continuing upward to 3,000 gallons and dual-vault series installations. Our UPC tab also cross-checks peak hourly meals served and menu grease intensity so operators remodeling a small footprint for high-volume fried chicken or barbecue spot capacity bottlenecks early.
Common sizing mistakes during restaurant lease takeovers
Second-generation restaurant spaces frequently inherit a trap sized for a prior tenant—such as a 20 GPM under-sink box left behind by a smoothie or sandwich shop. When the incoming concept adds a charbroiler, two fryers, and a high-temp dishmachine without re-running fixture math, two failures follow: wastewater inspectors flag the undersized unit during change-of-use review, or grease washes past the outlet baffle every weekend.
Before signing a commercial kitchen lease, measure the existing sink compartments, read the manufacturer data plate stamped on the interceptor cover (or check vault access lids in the alley), and run our 25 percent FOG rule tracker plus the commercial grease trap pumping cost planner to see how unit size affects annual pumping budgets.
Recording rated gallons on your kitchen pumping log
Once your trap or vault size is confirmed, write that rated gallon figure permanently onto your kitchen FOG maintenance log or outdoor grease interceptor pumping log. Knowing whether your tank holds 45 gallons indoors or 1,250 gallons beneath the back parking lot lets managers spot invoice discrepancies immediately—for instance, if a substitute driver bills for a 1,500-gallon haul on a 750-gallon vault.
For vendor vetting questions before your first service call, read our complete grease trap cleaning guide. When you are ready to put your unit label and next scheduled service date onto a clean one-page PDF with 30, 7, and 1-day email alerts, use the pre-filled checkout box above or compare all options on pricing.
Questions
01How do you convert 3-compartment sink inches into GPM for a grease trap?
Multiply length by width by water depth in inches, multiply by 3 compartments, divide by 231 cubic inches per gallon, multiply by 0.75 working capacity, and divide by either 1 minute or 2 minutes depending on local plumbing code.
02Why is required grease pound capacity twice the GPM flow rating?
Under PDI-G101 certification standards, hydromechanical grease interceptors must retain at least two pounds of grease at minimum 90 percent efficiency for every one gallon per minute of rated flow—so a 25 GPM unit holds at least 50 pounds.
03Can I connect a commercial dishwasher to an indoor under-sink grease trap?
Many local plumbing codes prohibit connecting high-temperature or chemical sanitizing dishmachines to small indoor hydromechanical traps because hot detergent water emulsifies grease and carries it straight through. Check your local code before connecting.
04Does this sizing calculator replace municipal pretreatment plan review?
No. Municipal sewer utilities and building departments often enforce local minimum tank sizes—such as a 750 or 1,000-gallon floor for full-service kitchens—that override textbook formulas. Always confirm with your local reviewer.