25 percent FOG rule tracker

Enter your interceptor static liquid depth, top floating grease cap thickness, settled bottom solids depth, and days since your last pump-out to calculate your exact combined FOG percentage right now. This 25 percent FOG rule tracker renders a proportional cross-section gauge of your tank, flags whether you sit inside the safe zone (<20%), the hauler booking window (20%–24.9%), or at/above the 25% threshold, and projects the calendar date your trap will reach 25%.

Sample Dip-Stick Readings:

Enter Trap Dip-Stick Measurements

Measure static liquid depth with the kitchen taps off, then enter top floating grease and settled bottom sludge.

Live Interceptor Cross-Section (48 in liquid)Combined: 22.9% of 25% cap
Top Floating Grease Cap6.5 in (13.5%)
Clear Separation Water Zone37 in (77.1%)
Settled Bottom Food Solids4.5 in (9.4%)
0% Clean20% Book Hauler25% FOG Limit50%+

Dip-Stick Binder Entry Preview

FOG DIP-STICK CHECK — Back Lot 1,000-Gal Interceptor
Check Date: 2026-11-25 (42 days since last pump-out)
Total Static Liquid Depth: 48.0 in
Top Floating Grease Cap:   6.5 in (13.5%)
Bottom Settled Solids:     4.5 in (9.4%)
Combined FOG + Solids:     11.0 in (22.9%) — BOOK HAULER (20-24%)
Projected 25% Threshold:   2026-11-28
Binder Note: Keep signed hauler ticket next to your one-page pumping log.

25% FOG + Solids Status

SCHEDULE NOW — Inside 20% to 24.9% Warning Zone

At 22.9% full, your interceptor is projected to reach 25% in about 3 days (2026-11-28). Book your hauler before peak weekend volume pushes grease past the outlet baffle.

Combined FOG + Solids
22.9%
11 in of 48 in total
Projected 25% Date
2026-11-28
In ~3 days (0.55%/day)
Floating Grease Cap
13.5%
6.5 in top mat
Settled Sludge Layer
9.4%
4.5 in bottom blanket
Inspector-Ready Log + 30/7/1-Day AlertsPDF emailed in 5 min

Lock in 2026-11-28 before you hit 25%

Email yourself the one-page binder PDF log now and get automatic 30, 7, and 1-day pump-out alerts on the date you set.

Annual emails the worksheet and sends reminders 30, 7, and 1 days before the date you enter.

Compare all 5 plans (from $19)

Free .ICS requires no email or card. Paid plans email a printable FOG pumping log PDF within 5 minutes + 30/7/1-day email reminders with no hidden overage fees.

Municipal pretreatment inspectors check both the physical tank layers and the kitchen paperwork binder. Even when your dip-stick percentage looks clean, an inspector can still ask where the last signed grease trap manifest is filed. Published company visit prices read 2026-11-13 were about $150 to $500 in El Paso, $200 to $500 in Boise, and $225 to $450 in Fairhope—vendor service prices, never a municipal interval rule.

Use the printable dip-stick preview to document routine checks, then lock your projected target date into our optional one-page PDF log with automated 30, 7, and 1-day email reminders ($39/year) so busy shifts never miss a booking window.

Schedule 30/7/1-day pump reminders

25% FOG + Settled Solids Depth Action Table

Many municipal wastewater pretreatment ordinances reference a combined 25% floating grease plus settled food solids threshold because separation efficiency drops sharply once one-quarter of the clear water zone is displaced. Always verify your local utility ordinance for site-specific limits.

Combined Depth BandFormula CheckHydraulic Separation StateRecommended Kitchen Action
0% to 19.9% (Safe Buffer)(Grease + Solids) ÷ Depth < 0.20Over 80% clear middle water zone intact for cooling and separationRecord dip reading in FOG binder; verify next reminder date is active
20.0% to 24.9% (Schedule Window)0.20 ≤ Combined Ratio < 0.25Approaching baffle short-circuit risk during Friday/Saturday dish surgesCall permitted hauler now so pump truck arrives before hitting 25%
25.0%+ (At / Over Limit)(Grease + Solids) ÷ Depth ≥ 0.25Emulsified grease and food solids can wash past outlet tee into sewer lateralBook immediate pump-out; retain signed hauler manifest and log filing spot

Run the companion kitchen compliance calculators

All calculators hub →

What wastewater utilities mean by the 25 percent FOG rule

Across hundreds of North American sewer authorities, wastewater ordinances pair a calendar maximum with a physical accumulation cap known as the 25 percent rule. In plain math, add the thickness of the floating fats, oils, and grease (FOG) mat at the top of the tank to the depth of settled food solids (sludge) on the floor of the tank, then divide that combined thickness by the total static liquid depth from the tank floor to the waterline.

Why 25 percent rather than 50 or 80 percent? Gravity and hydromechanical interceptors rely on hydraulic retention time—giving warm kitchen wastewater enough calm, clear middle-zone volume for lighter lipids to float upward and heavier food particles to settle downward before water exits beneath the outlet baffle. Once floating grease and bottom solids displace one-quarter of total liquid depth, incoming surge flow accelerates through a narrowed middle channel and carries unseparated grease into public sewer pipes.

Why measuring only the top grease cap misses half the violation risk

A frequent mistake in commercial kitchens is poking a broomstick through the top crust, seeing three inches of grease in a 36-inch-deep tank (8.3 percent), and assuming the unit has months of headroom left. Meanwhile, six inches of coffee grounds, fryer breading, rice starch, and vegetable pulp have settled across the bottom compartment—pushing combined grease plus solids to nine inches out of 36, or exactly 25.0 percent.

Bottom solids also decay anaerobically, generating hydrogen sulfide gas and organic acids that corrode concrete interceptor walls, eat cast-iron baffles, and release foul odors when manhole lids or indoor covers are opened. Measuring both top floating grease and bottom settled solids with a clear core sampler (“Sludge Judge”) or calibrated dip pole is the only honest way to track the 25 percent threshold.

How daily accumulation rate projects your next hauler booking date

When you know how many days have passed since a permitted hauler pumped and scraped the tank clean to zero, dividing current combined percentage by elapsed days yields an empirical daily accumulation rate for your actual menu and staff habits. For example, if an outdoor 1,000-gallon vault reaches 18.0 percent combined FOG + solids 36 days after a full pump-out, your kitchen is adding roughly 0.50 percent per day.

At 0.50 percent per day, the tank will cross the 20 percent early-scheduling buffer in four days (Day 40) and hit the 25 percent ceiling in 14 days (Day 50). Booking your permitted hauler inside the 20 to 24 percent window gives dispatchers a full week to route a vacuum truck at standard scheduled rates rather than paying emergency surcharges—which you can model in our commercial grease trap pumping cost calculator.

When your trap hits 25 percent too fast: check fixture sizing and prep habits

If dip-stick readings climb past 25 percent every two or three weeks despite dry-wiping pans and keeping sink strainers in place, the underlying issue may be hydraulic undersizing rather than sloppy line cooks. Run your three-compartment sink dimensions and connected DFUs through our restaurant grease trap sizing calculator to check whether kitchen volume has outgrown the installed trap.

Inside the kitchen, three zero-cost habits slow daily FOG buildup immediately: scraping fryer baskets, sheet pans, and ramekins into compost or trash before pre-rinsing; never pouring hot pan drippings or cloudy fryer boil-out water down floor drains; and keeping 1/8-inch perforated strainer baskets locked inside every pot-sink drain.

Pairing dip-stick checks with your manifest binder and reminder emails

Self-monitoring notes and hauler manifests serve two complementary roles during a municipal FOG check. Your dip-stick note shows active oversight between pump-outs; the hauler ticket proves a permitted liquid-waste transporter removed the full load; and our one-page FOG maintenance log indexes every service date, gallon figure, hauler name, and exact binder filing spot.

Read our main grease trap cleaning overview for vendor checklist questions, see the outdoor grease interceptor pumping log if you manage exterior manholes, or visit pricing to set up 30, 7, and 1-day email reminders around your target pump date.

Questions

01How is the 25 percent FOG percentage calculated during an inspection?

Add the top floating grease layer thickness in inches to the bottom settled solids depth in inches, divide that sum by the total static liquid depth of the compartment, and multiply by 100.

02Should we pump only the top grease layer or the entire interceptor?

Most municipal FOG programs prohibit skimming or decanting and require a full pump-out—removing floating grease, middle water, and bottom solids while scraping baffle walls—unless the local utility explicitly authorizes a permitted pump-and-return vehicle.

03Which compartment do inspectors dip in a two-compartment outdoor interceptor?

Inspectors typically measure the primary inlet compartment first because it captures the heaviest grease mat and food solids, though some utilities check both inlet and secondary outlet compartments. Confirm your local utility inspection protocol.

04Does hitting 22 percent violate a municipal 25 percent FOG rule?

Twenty-two percent is below a 25 percent threshold, unless your local utility enforces a stricter cap or a mandatory calendar schedule that comes due first. We flag 20 to 24.9 percent as the practical window to book a hauler before hitting 25 percent.