Skip to content
Grease Trap Due

Grease Trap Due

U.S. city grease trap FOG compliance guides

Commercial kitchen grease rules in the United States are enforced city by city—not by a single national calendar. A restaurant in Houston, San Antonio, or Milwaukee faces a mandatory 5-year on-site manifest retention rule, a Miami-Dade facility under a Grease Discharge Operating Permit must file electronic manifests by the 20th of the next month, a Portland kitchen submits maintenance reports to BES within 14 days, and a New York City kitchen must hire a BIC-licensed carter under 15 RCNY § 19-11. Use the interactive directory below to filter 52 major U.S. restaurant metros (publicly posted municipal pages read 2026-11-21) and jump directly to your water authority's compliance snapshot.

52 Major U.S. Restaurant Metros · Read 2026-11-21

Find your municipal pretreatment authority and manifest retention rule

Showing 52 of 52 cities

Filter by record-keeping pattern
NY3-year binder best practice

New York City

NYC DEP

15 RCNY § 19-11 25% depth cap, BIC-licensed carter proof, and DOB plan binder prep.

Open New York City FOG guide →

CA3-year minimum on-site

Los Angeles

LA Sanitation (LASAN)

LAMC § 64.30 IWMD inspections, 25% FOG limit, and 3-year on-site manifest storage.

Open Los Angeles FOG guide →

IL3-year O&M & manifest file

Chicago

Chicago DWM & MWRD

MCC Ch. 18-29 catch-basin rules, MWRD pretreatment limits, and 3-year O&M log books.

Open Chicago FOG guide →

TX5-year mandatory retention

Houston

Houston Health & Public Works

5-year manifest retention, full evacuation (no dewatering), and original FOG permit binder.

Open Houston FOG guide →

TX3-year trip ticket retention

Dallas

Dallas Water Utilities (DWU)

Ch. 19 Art. X official City trip tickets, TCEQ + DWU hauler permits, and 3-year file.

Open Dallas FOG guide →

TX3-year on-site (§ 15-10-165)

Austin

Austin Water

Austin Code § 15-10-165 3-year retention, 50% wetted-height trigger, and City-permitted haulers.

Open Austin FOG guide →

TX5-year + annual inspection

San Antonio

SAWS

5-year SAWS manifest retention, SAWS-permitted haulers, and annual photo inspection binder.

Open San Antonio FOG guide →

AZ3-year on-site retention

Phoenix

Phoenix Water Services

Ch. 28 indoor vs. outdoor schedules, 25% capacity limit, and 3-year on-site invoices.

Open Phoenix FOG guide →

WAOn-site log & 25% rule

Seattle

Seattle Public Utilities (SPU)

SPU 25% depth standard, commercial kitchen BMPs, and regional FOG provider receipts.

Open Seattle FOG guide →

CA3-year signed manifests

San Francisco

SFPUC

SFPUC 3-year on-site signed manifests, certified hauler tracking, and wastewater inspection prep.

Open San Francisco FOG guide →

FLe-Manifest by 20th + 3-yr

Miami-Dade County

Miami-Dade RER / DERM

GDO electronic manifest due 20th of next month, county-permitted haulers, and 3-year archive.

Open Miami-Dade County FOG guide →

GAFOG Permit + GA EPD manifest

Atlanta

Atlanta Watershed (DWM)

Code § 154-297.01 tiered FOG permits, GA EPD 391-3-6-.24 manifests, and multi-year audits.

Open Atlanta FOG guide →

CO3-year on-site records

Denver

Denver DOTI Wastewater

DRMC FOG compliance, licensed hauler volume tickets, and 3-year on-site inspection binder.

Open Denver FOG guide →

MABWSC Grease Control Log

Boston

Boston BWSC

Mandatory BWSC Grease Control Log, chemical solvent ban, and 500+ gal hauler receipts.

Open Boston FOG guide →

PA3-year PWD & L&I file

Philadelphia

Philadelphia Water (PWD)

PWD Ch. 5 wastewater control, L&I audit binder, and 3-year signed hauler manifests.

Open Philadelphia FOG guide →

NVOn-premises at all times

Las Vegas

Las Vegas & CCWRD

On-premises log mandate, CCWRD regional FOG rules, and Strip/valley hauler manifests.

Open Las Vegas FOG guide →

FLFL 1-yr statute / 3-yr audit

Orlando

Orlando Water Reclamation

FL three-party Service Manifests, 30-day disposal return rule, and Orlando Water audits.

Open Orlando FOG guide →

FL3-year mandatory on-site

Tampa

Tampa Wastewater Dept.

Article VII City-approved hauler manifests, registered transporters, and 3-year files.

Open Tampa FOG guide →

NC3-year + life-of-trap plans

Charlotte

Charlotte Water

3-year manifest retention, life-of-trap as-built drawings, and Charlotte Water audits.

Open Charlotte FOG guide →

TN3-year immediate access

Nashville

Nashville MWS

MWS 3-year immediate-access manifests, removed-gallon logs, and Metro Health prep.

Open Nashville FOG guide →

OR14-day report + 3-yr file

Portland

Portland BES

ENB-4.26 14-day BES reporting, Preferred Pumper option, and 3-year Title 17 archive.

Open Portland FOG guide →

CAFEWD permit + 3-yr file

San Diego

San Diego FEWD

Mandatory FEWD permit, 25% liquid depth rule, and on-site permitted hauler receipts.

Open San Diego FOG guide →

CASwiftComply e-Portal + log

San Jose

San Jose ESD

Code § 15.14.650 SwiftComply portal, monthly indoor / quarterly outdoor baseline.

Open San Jose FOG guide →

MN3-year signed manifests

Minneapolis

Minneapolis FOG & MCES

Dual-signed pumping manifests, T-down pipe condition notes, and 3-year MCES file.

Open Minneapolis FOG guide →

MI3–5 year IWC audit file

Detroit

Detroit DWSD & GLWA

DWSD/GLWA Industrial Waste Control compliance, 3–5 yr manifest binder, and audit prep.

Open Detroit FOG guide →

OH3-year BMP cleaning log

Columbus

Columbus Public Utilities

Director’s Rules FOG BMP, net grease/solids log, Satisfactory status, and 3-yr file.

Open Columbus FOG guide →

IN3–5 year signed manifests

Indianapolis

Citizens Energy Group

Citizens Energy 25% rule, signed trip tickets beyond invoices, and 3–5 yr storage.

Open Indianapolis FOG guide →

FLJEA FOG BMP + 3-yr file

Jacksonville

JEA Pretreatment

JEA FOG BMP online tracking, certified hauler uploads, and 3-year on-site binder.

Open Jacksonville FOG guide →

TX3-year + 100% pump-out

Fort Worth

Fort Worth Water

100% quarterly/25% evacuation, permitted TX haulers, and 3-year trip ticket binder.

Open Fort Worth FOG guide →

TX3-year original manifests

El Paso

El Paso Water (EPWater)

PSB multi-part original manifests, TCEQ + City registered haulers, and 3-year file.

Open El Paso FOG guide →

TNOn-site FOG binder + 25%

Memphis

Memphis Public Works

Memphis Code Ch. 33 FOG rules, certified haulers, and Environmental Engineering audits.

Open Memphis FOG guide →

KY3-yr log + manifests pair

Louisville

Louisville MSD

Requires both active log AND manifests together (3 yrs), 25% rule, MSD haulers.

Open Louisville FOG guide →

MD3–5 yr DPW audit binder

Baltimore

Baltimore City DPW

DPW 25% capacity rule, licensed hauler manifests, and 3–5 year on-site audit file.

Open Baltimore FOG guide →

WI5-year mandatory (Ch. 11)

Milwaukee

Milwaukee MMSD

MMSD Ch. 11 mandatory 5-year retention floor, enforcement extensions, and trip tickets.

Open Milwaukee FOG guide →

NM3-year mandatory onsite

Albuquerque

Albuquerque ABCWUA

ABCWUA 3-year onsite manifest retention, pretreatment audits, and binder tracking.

Open Albuquerque FOG guide →

AZ3-yr per-device log

Tucson

Pima County RWRD

Separate log per trap/interceptor, technician name & disposal site, 3-yr RWRD file.

Open Tucson FOG guide →

CA3-year + receiving tickets

Fresno

Fresno DPU Wastewater

FMC Ch. 6 Art. 3 FOG permits, truck ID receiving manifests, and 3-year DPU files.

Open Fresno FOG guide →

CACDFA 2-yr / 3-yr audit

Sacramento

SacSewer & Sacramento

CDFA IKG brown-grease chain of custody, quarterly outdoor evacuations, 3-yr audit file.

Open Sacramento FOG guide →

MO3-year on-site (§ 60-117)

Kansas City

KC Water

KCMO Code § 60-117 mandatory 3-year retention, condition checks, and KC Water audits.

Open Kansas City FOG guide →

NC3-year Wake/Raleigh binder

Raleigh

Raleigh Water

Raleigh Water FOG permits, Wake County health/utility binder, and 3-year receipts.

Open Raleigh FOG guide →

LA3-year on-site manifests

New Orleans

SWBNO Pretreatment

SWBNO 25% depth cap, LA DEQ-registered haulers, and 3-year French Quarter/Orleans files.

Open New Orleans FOG guide →

UT3-year on-site (Title 17)

Salt Lake City

Salt Lake City DPU

SLC Title 17.36 25% depth trigger, licensed UT haulers, and 3-year on-site binder.

Open Salt Lake City FOG guide →

DC3-year on-site (21 DCMR)

Washington, D.C.

DC Water Pretreatment

21 DCMR Ch. 15 25% depth cap, DC Water & DC Health inspections, and 3-year files.

Open Washington, D.C. FOG guide →

NJ3-year NJDEP & PVSC file

Newark

Newark Water & PVSC

PVSC pretreatment rules, NJDEP-licensed haulers, 25% cap, and 3-year binder.

Open Newark FOG guide →

PA3-year PWSA & ACHD file

Pittsburgh

PWSA & ACHD

PWSA/ALCOSAN & ACHD Article XV compliance, 25% rule, and 3-year manifest file.

Open Pittsburgh FOG guide →

OH3-year on-site (Art. XV)

Cincinnati

Cincinnati MSDGC

MSDGC Article XV 25% depth rule, full evacuation, and 3-year Greater Cincinnati logs.

Open Cincinnati FOG guide →

OH3-year NEORSD audit file

Cleveland

Cleveland NEORSD

NEORSD Title II sewer-use rules, no chemical emulsifiers, and 3-year manifest file.

Open Cleveland FOG guide →

MO3-year MSD binder

St. Louis

St. Louis MSD

MSD Ordinance 15714 25% capacity cap, permitted haulers, and 3-year STL files.

Open St. Louis FOG guide →

VA3-year on-site (Ch. 28)

Richmond

Richmond DPU FOG

Richmond Code Ch. 28 Art. VIII 25% cap, DPU & VDH checks, and 3-year binder.

Open Richmond FOG guide →

VA3-year HRFOG certified

Virginia Beach

Virginia Beach & HRSD

Hampton Roads Regional FOG (HRFOG) certified haulers, 25% rule, and 3-year logs.

Open Virginia Beach FOG guide →

OK3-year on-site (Ch. 47)

Oklahoma City

OKC Utilities FOG

OKC Code Ch. 47 City-permitted haulers, 25% depth trigger, and 3-year binder.

Open Oklahoma City FOG guide →

CA3-year EBMUD & IKG file

Oakland

Oakland & EBMUD

EBMUD Title II Source Control, CA CDFA IKG licensed haulers, and 3-year audit file.

Open Oakland FOG guide →

Every city page pairs verified local agency links with a ready-to-fill pumping log workspace while respecting a clear boundary: Grease Trap Due does not perform physical grease trap cleaning, inspect underground vaults, or submit municipal e-manifests. Your permitted liquid waste hauler evacuates the trap and signs the disposal ticket; your kitchen files that grease trap manifest inside an on-site compliance binder and uses our log and reminder emails to prevent missed cycles.

If your municipality is outside these 52 metro guides—or if your restaurant group runs kitchens across multiple suburbs with different sanitary districts—the underlying binder habit is identical everywhere: confirm your local ordinance directly with your sewer authority, record every pump-out date and removed gallon count in one place, and schedule reminders far enough ahead to book a permitted vacuum truck before an inspector arrives.

Build your kitchen pumping log

Why municipal FOG rules differ across major U.S. metros

Although almost every municipal pretreatment division shares the same engineering goal—keeping animal fats, cooking oils, and food solids from choking public sewer mains—each city codifies its own inspection cadence, permit structure, and paperwork lookback window. Older combined-sewer cities such as New York, Boston, Chicago, Philadelphia, Milwaukee, and Baltimore emphasize strict prohibitions on chemical emulsifiers, food-waste grinders, and unapproved plumbing tie-ins alongside multi-year maintenance log books.

Fast-growing Sunbelt and Texas metros including Houston, Dallas, Fort Worth, Austin, San Antonio, El Paso, and Phoenix place heavy enforcement weight on numbered waste trip tickets, city-permitted special waste transporters, full 100% evacuation (prohibiting mobile dewatering), and multi-year lookback audits stretching three to five full years. Meanwhile, digital-first utilities such as Miami-Dade RER/DERM, San Jose SwiftComply, Jacksonville JEA FOG BMP, and Portland BES combine physical binder checks with recurring electronic reporting deadlines.

Because those differences sit inside local municipal codes rather than federal statutes, relying on a generic internet rule of thumb can leave a multi-unit operator exposed in the wrong jurisdiction. Comparing your city profile here before meeting a hauler or city inspector lets you verify exact terminology—whether your inspector asks for a BWSC Grease Control Log, a DWU Liquid Waste Trip Ticket, a Louisville MSD paired log and manifest, a Pima County RWRD per-device sheet, or a Miami-Dade GDO e-manifest confirmation.

Four universal records every city water inspector checks first

Across all 52 metros summarized in this directory, unannounced walkthroughs follow a remarkably consistent opening script. Inspectors start at the manager desk before lifting a single manhole cover: they ask to see proof of your active municipal FOG permit (where required), your chronological FOG maintenance log, signed waste manifests from a permitted liquid-waste transporter, and proof that service frequency keeps accumulated grease and solids below local depth thresholds.

When any one of those four pieces is missing—most commonly because a departing manager took vendor emails with them or a shift lead cannot remember which drawer holds last quarter’s receipts—inspectors treat the gap as an unverified compliance period. Writing the physical binder location directly onto your cover sheet turns an anxious ten-minute search into a calm thirty-second handoff.

Pair your city guide with our three free browser tools inside the grease trap calculators hub: verify whether your tank is properly sized with the sizing calculator, measure floating fat plus bottom sludge with the 25% FOG rule tracker, and benchmark annual hauling spend with the pumping cost estimator.

How we verify municipal sources and keep the scope honest

Each city guide in this directory was compiled by reading publicly posted municipal pretreatment and water-utility program information on 2026-11-21, citing the regulating agency, municipal code chapter, manifest retention expectation, hauler permitting authority, and official agency URL. We link straight to the public utility portal so restaurant owners can confirm fee schedules, approved hauler directories, and any recent ordinance revisions firsthand.

To prevent outdated assumptions from ever misleading a kitchen operator, our downloadable pumping log PDF never prints a hardcoded city interval. Your permit variance, seating count, frying volume, and sludge-judge depth readings determine when your next truck should arrive. You type that verified next date into our checkout or log workspace, receive your printable PDF within 5 minutes, and let our 30-day, 7-day, and 1-day email reminders protect your team from forgetting.

See how the PDF is emailed for the exact delivery timeline and 6-digit account sign-in flow, or compare single-store and five-location options on the pricing page.

Before renewing any annual commercial pumping agreement, cross-check your city guide against the actual invoice terms offered by permitted haulers in your metro. Verify whether routine quotes include full chamber evacuation, scraping interior baffles, and written disposal-site confirmation, and confirm whether your municipality requires you to keep paper trip tickets on-site or submit electronic confirmation numbers through a municipal portal each billing period. Capturing those rules once in your kitchen compliance binder eliminates repeat scramble calls before health or wastewater inspections.

Questions

01What if my restaurant city is not listed in these 52 metro guides yet?

Use the universal grease trap manifest builder directly. It records the exact four fields every U.S. pretreatment inspector reviews—date pumped, gallons or unknown, permitted hauler name, and physical binder location—plus your verified next reminder date.

02Why do Houston, San Antonio, and Milwaukee require 5 years of manifests while other cities require 3 years?

Local municipal ordinances set their own enforcement lookback windows. Houston Chapter 47, San Antonio SAWS Chapter 34, and Milwaukee MMSD Chapter 11 all enforce 5-year retention rules, whereas cities such as Dallas, Austin, Los Angeles, Phoenix, San Francisco, Denver, Columbus, Kansas City, and Philadelphia enforce a 3-year on-site retention baseline.

03Can one Grease Trap Due plan cover restaurants in multiple cities?

Yes. Our 5-location annual ($149/year) and 5-location lifetime ($999) plans on the pricing page let multi-unit operators maintain separate store labels, hauler details, and independent reminder dates across up to five kitchens in any U.S. municipality.

04Are chemical enzymes or grease-dissolving additives allowed in these cities?

Many major utilities—including NYC DEP, Chicago MWRD, Las Vegas valley sanitation, and Boston BWSC—explicitly prohibit chemical emulsifiers, solvents, or unapproved biological additives that push grease downstream into public sewers. Always confirm additive restrictions directly with your municipal pretreatment division before using any drain treatment.

U.S. City Grease Trap FOG Compliance & Log Guides (2026)