Skip to content
Grease Trap Due

Grease Trap Due

Commercial grease trap calculators

Commercial kitchen managers, chef-owners, and multi-unit facilities teams use three recurring math checks to keep wastewater binders organized: fixture flow and tank sizing, floating grease plus settled solids percentage checks, and annual hauler pumping budget projections. Run any of the three zero-login calculators below in your browser, then carry your unit label, gallon rating, and next scheduled date straight into a printable one-page pumping log.

Run any calculator instantly right here:

1-Click Kitchen Presets:

Sizing Method & Fixture Inputs

Zero login required

Formula notice: PDI-G101 divides working sink volume (L × W × D × bowls ÷ 231 × fill) by drain minutes; UPC Table 1014.3.6 maps connected DFUs to gravity vault gallons. Your local plumbing official or pretreatment engineer approves final equipment sizing.

PDI-G101 Hydromechanical Rating

100 GPM / 200 lb PDI Hydromechanical Unit

Calculated at 86.5 GPM (75% sink fill, 1-min drain). Verify whether your local wastewater authority permits indoor hydromechanical units or requires an outdoor gravity tank.

Calculated Peak Flow
86.5 GPM
Sink 78.5 GPM + 8 extra
Min Grease Retention (2× GPM)
200 lbs
Standard 100 GPM HGI
UPC Table 1014.3.6 Vault
1,000 gal
Based on 28 connected DFUs
Peak-Meal Vault Cross-Check
500 gal
85 peak-hr meals
Inspector-Ready Log + 30/7/1-Day AlertsPDF emailed in 5 min

Pre-fill this unit into your one-page pumping log

Carry "Fast Casual Main Kitchen" (140 gal) straight into a printable binder PDF plus 30, 7, and 1-day pump-out email reminders.

Annual emails the worksheet and sends reminders 30, 7, and 1 days before the date you enter.

Compare all 5 plans (from $19)

Free .ICS requires no email or card. Paid plans email a printable FOG pumping log PDF within 5 minutes + 30/7/1-day email reminders with no hidden overage fees.

Every calculator on this hub separates engineering or planning formulas from binding local rules. Published company visit ranges read 2026-11-13—about $150 to $500 in El Paso, $200 to $500 in Boise, and $225 to $450 in Fairhope—reflect private vendor pages rather than municipal fee schedules. Always verify final equipment approval, depth limits, and mandatory service intervals directly with your local sewer authority.

Once you know your unit capacity or target service date, our optional paid workflow emails a tailored one-page PDF log within five minutes ($19 one-time, or $39 per year with automated 30, 7, and 1-day email reminders before the date you enter).

Compare PDF log & reminder plans

Which Kitchen Compliance Calculator Should You Run First?

Kitchen QuestionCalculatorInputs NeededOutput & Binder Handoff
Opening, remodeling, or checking fixture capacitySizing CalculatorSink L × W × D inches or connected DFUs + peak mealsGPM, grease lbs (2× GPM), or UPC gravity gallons
Checking dip-stick depth before an inspection25% FOG Rule TrackerLiquid depth, top grease cap, bottom solids, days since pumpCombined %, tank cross-section gauge, projected 25% date
Planning annual hauler spend across 1–5 storesPumping Cost EstimatorIndoor lb vs. outdoor gal, schedule cycle, metro multiplierPer-visit range, annual budget, surcharge ROI vs. $39/yr alerts

Why kitchen operators run sizing, depth, and budget math together

A grease trap decision rarely happens in isolation. When a restaurant signs a second-generation lease, adds an espresso bar, or swaps a prep table for a high-output fryer line, fixture discharge changes both equipment capacity and how fast floating fats, oils, and grease accumulate between hauler visits. Running a restaurant grease trap sizing calculator alongside a 25 percent FOG rule tracker shows why an undersized under-sink unit fills far faster than an outdoor underground gravity vault.

The third piece is operating budget. Kitchen operators comparing an indoor hydromechanical trap against an exterior interceptor can open the commercial grease trap pumping cost planner to model per-visit service ranges across monthly, 60-day, or quarterly 90-day schedules before asking local permitted haulers for written quotes.

How PDI-G101 hydromechanical sizing differs from UPC gravity sizing

Indoor under-sink and recessed floor units are typically rated under Plumbing and Drainage Institute standard PDI-G101 in gallons per minute (GPM) and pounds of grease retention, where minimum grease pound capacity equals twice the GPM flow rating. You measure each sink bowl in inches, divide cubic inches by 231 to convert to US gallons, apply the working fill factor, and divide by a one-minute or two-minute drainage period.

Large commercial sculleries, high-temperature dishmachines, tilt skillets, and wok ranges usually step outside indoor hydromechanical limits and fall under Uniform Plumbing Code Chapter 10 gravity interceptor tables. Those tables convert connected Drainage Fixture Units (DFUs) into precast concrete or fiberglass vault volumes starting around 500 gallons and scaling past 2,000 gallons, with many engineers also cross-checking peak hourly meal volume.

Understanding the combined 25 percent grease and solids threshold

Many municipal wastewater pretreatment utilities evaluate interceptor condition using a combined 25 percent rule: when the top floating grease cap plus the bottom settled food-solids blanket reaches one-quarter of total static liquid depth, clear separation volume shrinks enough that warm grease droplets can wash past the outlet tee into the public sewer collection main.

Tracking both layers together matters because a kitchen that scrapes plates poorly can accumulate heavy starch, rice, and breading sludge on the tank floor even when the top grease mat looks thin. Entering both dip-stick measurements gives managers an early 20 percent scheduling buffer before a surprise sewer inspection or Friday-night drain backup.

Turning calculator numbers into a permanent kitchen binder habit

Numbers on a phone screen disappear when shifts change. After a permitted hauler services the unit and leaves a signed grease trap manifest, someone on site still has to file that paper where the next manager can find it in under sixty seconds. Pairing your calculated gallon figure with a printed cover log keeps the date pumped, gallons or unknown, hauler name, and exact binder location on a single sheet.

For background on what questions to ask a permitted hauler before booking your first visit, read our main grease trap cleaning guide, compare dedicated templates on the FOG maintenance log and grease interceptor pumping log pages, or review all five reminder plans on the pricing page.

Scope boundaries: formulas assist planning, local authorities govern

Grease Trap Due is an independent digital publisher of printable PDF binder checklists and calendar email reminders. None of the calculators on this hub constitute professional engineering stamps, plumbing code approvals, municipal variance calculations, or contractor bids.

Plumbing inspectors, sanitary districts, and municipal pretreatment coordinators regularly adopt local amendments—such as prohibiting indoor traps on dishmachines, requiring minimum 1,000-gallon exterior tanks for fryers, or mandating specific pumping schedules regardless of dip-stick percentage. Always confirm the controlling local rule in writing with the authority having jurisdiction over your address.

Standardizing calculator records across multi-store kitchen teams

Area directors and facilities coordinators overseeing two to five locations face an extra challenge: one store may run a compact indoor hydromechanical unit under a sandwich prep sink while another store operates a 1,500-gallon concrete gravity vault behind a drive-thru lane. Mixing their gallon ratings, hauler contacts, or service cycles onto a generic spreadsheet invites missed appointments whenever a general manager transfers between stores.

Run each store independently through the calculators below, label each PDF cover sheet with the exact store name and fixture location, and keep each store physical binder next to the manager desk so any shift lead on duty can answer a wastewater records check immediately.

Questions

01Do I need an account or email address to use these three calculators?

No. All three calculators run instantly in your browser with zero login. You only enter an email address if you decide to buy a printable PDF pumping log and scheduled reminder plan.

02Can a calculator output substitute for a licensed plumber or city approval?

Never. Local plumbing codes and municipal wastewater programs enforce their own amendments, minimum vault sizes, and fixture rules. Treat calculator results as preliminary planning numbers to verify with your local authority.

03How do calculator values carry over to the printable PDF checklist?

When you use the checkout card beside any calculator result or click through to the pricing page, your kitchen unit label, gallon figure, and chosen reminder date pre-fill automatically so you never retype them.

04What if our restaurant group operates multiple traps across several addresses?

The Multi-Location Annual plan ($149/year) and Multi-Location Lifetime plan ($999) track up to five independent trap dates and unit labels under one account.

Grease Trap Calculators: Sizing, 25% FOG & Cost Tools